Indirect Fired 1,000,000 BTU heaters are available in natural gas or diesel fueled versions. Built to Canadian standards for efficiency, pushing over 13,000 CFM, these heaters are still narrow enough to fit through a standard door. For maximum efficiency (as with many of our heaters) it is recommended that air is recirculated in the space, rather than using 100% outside air…doing so can reduce fuel consumption by half. 1,000,000 BTU’s requires approximately 7 gallons per hour of fuel, On Site Energy rents temporary double wall UL Listed fuel tanks ranging from 250 gallons to 2,300 gallons capacity. Indirect Fired 400,000 BTU heaters provide clean heat using only a 110 volt outlet.
Generator sets and power cable can be utilized to provide turnkey contained heating systems on an emergency or planned basis. Heater rental solutions available 24/7/365 from any of our 3 branch locations, serving tri-state NY, NJ and CT areas and our Austin, IN branch serving the Midwest USA.
INDIRECT FIRED PROPANE OR NATURAL GAS HEATERS
400,000 BTU Heater:
- Heavy duty indirect fired ductable clean air heater

- Fuel can be propane or natural gas
- Units can be used indoors or outdoors
- For outdoor use the unit utilizes two 15' long 12" flexible ducts
- For indoor use the exhaust must be piped outside of the space - Plugs into a standard wall outlet
- Fits through a standard doorway
- The equivalent of a 117 kW electric heater
- Thermostat with 25' cord
1,000,000 BTU Heater:
- Heater is mobile & easy to position around the job site with integrated fork lift pockets
and lifting eyes - Units are CSA/UL Approved
- Unique high static fan allows recirculation of warm inside air, resulting in fuel savings and even temperatures
- Tempered air mode for LEED construction allows for lower discharge temperatures when remote thermostat is satisfied in order to deliver continuous heat to the jobsite
- Variable fan control (3 speeds) provides flexibility in CFM delivery and heat rise, up to 200°F
- VFD eliminates large in-rush current for motor starts.
- Single phase 208-240 volt or three phase 208-240 volt operation
- Units are very quiet
- Fits through a standard 36" door
- Units can be used indoors or outdoors

Heater Accessory - Destratification Fan for more effective heat and lower operating cost..
|
Fuel Consumption |
Dimensions (L x W x H) |
Air Flow (CFM) |
Pressure |
Air |
Power Requirements |
Approvals (Listed) |
Weight (lbs.) |
|---|---|---|---|---|---|---|---|---|
| 400,000 Propane | 4.25 GPH | 5' 10" x 2' 0" x 3' 11" | 2,500 | 3.2" WC | 2 x 12" | 115 volt, 15 amps |
cWHus, ETL | 365 |
| 400,000 Natural Gas |
390 CFH | 5' 10" x 2' 0" x 3' 11" | 2,500 | 2.0" WC | 2 x 12" | 115 volt, 15 amps | cWHus, ETL | 365 |
| 1.0 million Propane |
10.93 GPH | 9' 3" x 3' 9" x 4' 2" | 13,500 | 9.0" WC | 24" | 208 volt, 25 amps, 3 Phase** |
CSA/UL | 2,000 |
| 1.0 million Natural Gas |
1,000 CFH | 9' 3" x 3' 9" x 4' 2" | 13,500 | 9.0" WC | 24" | 208 volt, 25 amps, 3 phase** |
CSA/UL | 2,000 |
27.68" WC = 1 PSI
*** Can also use 240 volt, single phase, 42 amps